    arm64: dts: sdm845: Bind CPU thermal throttling to cluster sensors · 78f50df5
    Valentin Schneider authored and Ionela Voinescu's avatar Ionela Voinescu committed
    
    
    The previous commit removed per-CPU thermal zones. Despite having a thermal
    sensor per-CPU, the trip points in those zones would affect *several* CPUs:
    this system doesn't have per-CPU DVFS, so one cannot change the frequency
    of an individual CPU, but rather a group thereof (i.e. the frequency
    domain).
    
    Furthermore, the (existing) CPU cluster thermal zones have a "hot" trip
    point set at the same trip temperature as the lower per-CPU thermal
    zones. AIUI this is actually useless, as the struct thermal_zone_device_ops
    provided by thermal_of.c doesn't contain a .notify() callback, so no action
    will (and can) be taken as a consequence of hitting that trip point.
    
    Copy the previous per-CPU trip points / cooling maps into the CPU cluster
    thermal zones. This should effectively lead to a similar CPU thermal
    management as before with less overhead.
    
    Signed-off-by: default avatarValentin Schneider <valentin.schneider@arm.com>